Product DescriptionThermostat Automatic Constant Temperature and Humidity Control Board Dual Output
Description:
It is a digital temperature/humidity controller module.LCD display, very clear, easy to use, powerful.It can be widely used at Smart home,Industrial control,Automatic irrigation,Indoor ventilation.Protection equipment.
XY-WTH1 Temperature and humidity control module high precision digital display word double output automatic constant temperature and humidity control panel.
Product adopts industrial-grade chip, high-precision SHT20 temperature and humidity sensor
2.Features:
1>.LCD high definition display;
2>.Power-down memory function;
3>.Real-time display temperature;
4>.Real-time display humidity;
5>.Automatically save parameters;
6>.Support UART Set;
7>.Support measurement temperature and humidity at the same time;
8>.Work status indicator;
9>.Working mode is automatically adjusted;
10>.Independent of parameters;
11>.With case, beautiful and practical;
12>.High precision detection;
13>.Multiple parameters are displayed simultaneously.
3.Parameters:
1>.Product Name:Humidity Temperature Controller
2>.Product Number:XY-WTH1
3>.Working Voltage:DC 6V-30V
4>.Control Load Current:10A(Max)
5>.LCD refresh rate:0.5 second
6>.Sensor:SHT20 Humidity Temperature sensor
7>.Temperature range:-20℃~60℃
8>.Temperature Control precision:0.1℃
9>.Humidity range:0%-100%RH
10>.Humidity Control precision:0.1%RH
11>.UART Data transmission cycle:1.0 second
12>.Size of Controller:79*43*35mm
13>.Size of Sensor probe:60*30*20mm
14>.Length of Sensor cable:1.0 meter
4.Temperature function:
1>.Automatic recognition of working mode:
The module automatically selects the working mode according to the Start Temperature and Stop Temperature.
Start Temperature is more than stop temperature, Turn ON cooling mode 'C'.
Start temperature is less than stop temperature, Turn ON heating mode 'H'.
2>.Cooling Mode 'C':
Relay turn ON and Red Indicator turn ON and Refrigeration equipment starts working if connect load when Current Temperature is more than Start Temperature.
Relay turn OFF and Red Indicator turn OFF and Refrigeration equipment stops working if connect load when Current Temperature is less than Stop Temperature.
3>.Heating mode 'H':
Relay turn ON and Red Indicator turn ON and Heating equipment starts working if connect load when Current Temperature is less than Start Temperature.
Relay turn OFF and Red Indicator turn OFF and Heating equipment stops working if connect load when Current Temperature is more than Stop Temperature.
4>.Temperature Correction ‘ OFE ’(-10.0~10.0℃):
The system may have errors if it works for a long time, it can be corrected by this function.
Actual Temperature = Measured Temperature + Calibration Value.
Setting method:
4.1>.Double-click button 'TM+' in the normal running interface into Temperature Correction setting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.
4.2>.Switch to select modified parameters by short press button ‘TM-’.
4.3>.Short press button ‘RH+’ and ‘RH-’ to set the specific value.Support long press.
4.4>.After the parameters have been modified, double-click button ‘TM+’ to save the data and exit the correction value setting interface.
5>.Set Start/Stop Temperature:
Keep press button 'TM+' for 3second in the normal running interface into Start Temperature setting interface.Short press button 'TM+' or 'TM-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
Keep press button 'TM-' for 3second in the normal running interface into Stop Temperature setting interface.Short press button 'TM+' or 'TM-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
6>.Relay enable (default on):
Short press button ‘TM-’ in the normal running interface.Turn ON or OFF temperature relay output enable.Screen will display ‘℃’ and flashes if If the temperature relay is OFF.
5.Humidity function:
1>.Automatic recognition of working mode:
The module automatically selects the working mode according to the Start Humidity and Stop Humidity.
Start Humidity is more than stop Humidity, Turn ON dehumidification mode 'd'.
Start Humidity is less than stop Humidity, Turn ON humidification mode 'E'.
2>.Dehumidification Mode 'd':
Relay turn ON and Green Indicator turn ON and Dehumidification equipment starts working if connect load when Current Humidity is more than Start Humidity.
Relay turn OFF and RED Indicator turn OFF and Dehumidification equipment stops working if connect load when Current Humidity is less than Stop Humidity.
3>.Humidification mode 'E':
Relay turn ON and Green Indicator turn ON and Humidification equipment starts working if connect load when Current Humidity is less than Start Humidity.
Relay turn OFF and Green Indicator turn OFF and Humidification equipment stops working if connect load when Current Humidity is more than Stop Humidity.
4>.Humidity Correction ‘ RH ’(-10.0~10.0%RH):
The system may have errors if it works for a long time, it can be corrected by this function.
Actual Humidity= Measured Humidity+ Calibration Value.
4.1>.Double-click button 'TM+' in the normal running interface into Temperature Correction setting interface.The first line shows the type of correction value(OFE or RH).The second line shows the specific value.
4.2>.Switch to select modified parameters by short press button ‘TM-’4.3>.Short press button ‘RH+’ and ‘RH-’ to set the specific value.Support long press.
4.4>.After the parameters have been modified, double-click button ‘TM+’ to save the data and exit the correction value setting interface.
5>.Set Start/Stop Humidity:
Keep press button 'RH+' for 3second in the normal running interface into Start Humidity setting interface.Short press button 'RH+' or 'RH-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
Keep press button 'RH-' for 3second in the normal running interface into Stop Humidity setting interface.Short press button 'RH+' or 'RH-' to set parameters value.After the parameters are modified and then wait for 6s to automatically save and exit.
6>.Relay enable (default on):
Short press button ‘RH-’ in the normal running interface.Turn ON or OFF humidity relay output enable.Screen will display ‘%’ and flashes if If the temperature relay is OFF.
6.Additional Features:
1>.Set or read data by UART.
Parameters such as start temperature/humidity, stop temperature/humidity, temperature/humidity correction, etc. can be set through the UART.
2>.Temperature/Humidity real-time reporting.
The controller module will report the current temperature/humidity to the terminal equipment by the UART at intervals of 1 second to facilitate data acquisition if the temperature/humidity reporting function is turned ON.
3>.Relay enable (default on).
If the relay enable is turned off, the relay remains off.
That is, the output state will never change, no matter what the measured temperature/humidity is.
7.Use steps:
1>.Connect sensor to controller;
2>.Connect to power supply to controller;
3>.Adjust Start Temperature,Stop temperature and Temperature Correction;
4>.Adjust Start Humidity,Stop Humidity and Humidity Correction;
5>.Enable relay output according requirement;
6>.Remove power supply;
7>.Connect to load with power supply at relay output terminal if need at Step5;
8>.Connect to power supply for controller again;
9>.Test and working!
8.UART communication and parameter settings
The system supports UART data upload and parameter setting functions (TTL level);
UART: 9600, 8, 1
1>:start : Start test value report
2>:stop : Stop test value report
3>:read : Read setting parameters
4>:T:ON : Temperature Relay enable ON
5>:T:OFF : Temperature Relay enable OFF
6>:H:ON : Humidity Relay enable ON
7>:H:OFF : Humidity Relay enable OFF
8>:TS:XX.X : Set Start Temperature Value (-20.0~60.0℃)
9>:TP:XX.X : Set Stop Temperature Value (-20.0~60.0℃)
10>:HS:XX.X : Set Start Humidity Value (00.0%~100.0%RH)
11>:HP:XX.X : Set Stop Humidity Value (00.0%~100.0%RH)
12>:TC:XX.X : Temperature calibration (-10.0~10.0℃)
13>:HC:XX.X : Humidity calibration (-10.0~10.0%RH)
Temperature and humidity data upload format:
Temperature format: work mode (H/C), Current Temperature, Temperature relay status;
Humidity format: work mode (E/D), Current Humidity, Humidity relay status;
For example:
H, 20.5℃, CL: Heating Mode, Current Temperature 20.5℃, Temperature relay is OFF.
D,50.4%,OP:Dehumidification mode,Current Humidity 50.4%RH,Humidity relay is ON.
9.Application:
Control cabinet;
Production workshop;
Hatching aquaculture control;
Tobacco industry;
Printing house;
Aquarium temperature control;
Bedroom.
10.Note:
It is a relay output mode and cannot be used as a power module. It cannot output voltage. The load needs to be connected to a separate power supply.
Package List:
1 x XY-WTH1 Humidity Temperature Controller
1 x SHT20 Sensor
About Us
Payment
Shipping
Returns
Contact Us
● We can supply a wide range of products to meet the ever-changing market demands. Customized orders are welcomed. We annually produce 5000 pieces per day. Our products sell well in North America, West Europe and Australia. Our company insists on the principle of "Good service, the best quality and competitive price"
● We are increasingly expanding international markets based on quality products, excellent service, reasonable prices and timely delivery. Please contact us at any time for more information.
● We only accept PayPal.
● All auction items must be prepaid in full.
● All payments are expected within 7 days after the winning auction is closed. If not, unpaid item dispute will be filed to eBay.
1.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
2.Items will be shipped within 1-5 business day when we received payment.
3.Delivery time depends on destination and other factors;
4.International buyers please note:
a.Import duties, taxes and charges are not included in the item price or shipping charges. These charges are buyer’s responsibility. We will try our best to reduce the risk of the custom duties.
b.Please check with your country's customs office to determine what these additional costs will be prior to buying.
● If the item you received is defective in any way, we will exchange it if possible or refund the money. Please contact me first.
● Refund is not allowed if you purchased the wrong item, replacement is the only option.
● Replacement or refund will be made upon receipt the returned item. In all cases, buyers pay for shipping at their own cost to return products for exchange or refund, sellers pay for the resending fee.
● Please don't leave any negative or neutral feedback before email your problem to us . We will help you to solve the problem.
● Once your item arrives in satisfactory condition, please leave a positive feedback for us.
● If you have any question,please just feel free to contact me. Thanks!
About Us
● We can supply a wide range of products to meet the ever-changing market demands. Customized orders are welcomed. We annually produce 5000 pieces per day. Our products sell well in North America, West Europe and Australia. Our company insists on the principle of "Good service, the best quality and competitive price"
● We are increasingly expanding international markets based on quality products, excellent service, reasonable prices and timely delivery. Please contact us at any time for more information.
Payment
● We only accept PayPal.
● All auction items must be prepaid in full.
● All payments are expected within 7 days after the winning auction is closed. If not, unpaid item dispute will be filed to eBay.
Shipping
1.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
2.Items will be shipped within 1-5 business day when we received payment.
3.Delivery time depends on destination and other factors;
4.International buyers please note:
a.Import duties, taxes and charges are not included in the item price or shipping charges. These charges are buyer’s responsibility. We will try our best to reduce the risk of the custom duties.
b.Please check with your country's customs office to determine what these additional costs will be prior to buying.
Returns
● If the item you received is defective in any way, we will exchange it if possible or refund the money. Please contact me first.
● Refund is not allowed if you purchased the wrong item, replacement is the only option.
● Replacement or refund will be made upon receipt the returned item. In all cases, buyers pay for shipping at their own cost to return products for exchange or refund, sellers pay for the resending fee.
Contact Us
● Please don't leave any negative or neutral feedback before email your problem to us . We will help you to solve the problem.
● Once your item arrives in satisfactory condition, please leave a positive feedback for us.
● If you have any question,please just feel free to contact me. Thanks!
powered by